Absorption Chillers

Vivamus consectetuer hendrerit lacus. Vivamus quis mi. Nulla porta dolor. Duis arcu 

Absorption Chillers

HOT WATER

  1. Single effect Hot Water
  2. Model: YHAU-CHW 30-200 TR
  3. Capacity: 105-704 kW
  4. Applications: Combined heat and power (CHP), commercial cooling, industrial process cooling

LOW TEMPERATURE HOT WATER

  1. Single Effect Double Lift Hot Water
  2. Model: YHAU-CL-DXS
  3. Capacity: 176 – 4,395 kW / 50 – 1,250 TR
  4. Application: Combined heat and power (CHP), commercial cooling, industrial process cooling

LOW PRESSURE STEAM

  1. Single Effect Steam
  2. Model: YHAU-C
  3. Capacity: 105 – 7,034 kW / 30 – 2,000 TR
  4. Application: Combined heat and power (CHP), commercial cooling, industrial process cooling

MEDIUM PRESSURE STEAM

  1. Double Effect Steam
  2. Model: YHAU-CW
  3. Capacity: 422 – 14,067 kW / 120 – 4,000 TR
  4. Application: Combined heat and power (CHP), commercial cooling, industrial process cooling

DIRECT FIRED

  1. Small Double Effect Natural Gas or Light Oil*
  2. Model: YHAU-CG/CA-CYR
  3. Capacity: 105 – 352 kW / 30 – 100 TR
  4. Application: Commercial cooling

DIRECT FIRED

  1. Large Double Effect Natural Gas or Light Oil
  2. Model: YHAU-CG/CA
  3. Capacity: 422 – 5,626 kW / 120 – 1,600 TR
  4. Application: Commercial cooling, industrial process cooling

EXHAUST GAS

  1. Double Effect Exhaust Gas
  2. Model: YHAU-CE
  3. Capacity: 527 – 5,064 kW / 150 – 1,440 TR
  4. Application: Combined heat and power (CHP), commercial cooling

EXHAUST GAS AND LOW TEMPERATURE HOT WATER

  1. Multi Energy Exhaust and Jacket Hot Water
  2. Model: YHAU-CE-J
  3. Capacity: 527 – 5,064 kW / 150 – 1,440 TR
  4. Application: Combined heat and power (CHP), commercial cooling

EXHAUST GAS AND LOW TEMPERATURE HOT WATER AND DIRECT FIRED

  1. Multi Energy Exhaust, Jacket Hot Water, Direct Fired
  2. Model: YHAU-CGE-J
  3. Capacity: Custom
  4. Application: Combined heat and power (CHP), commercial cooling

NATURAL GAS AND LOW TEMPERATURE HOT WATER

  1. Gas Gene-Link
  2. Model: YHAU-CG-J
  3. Capacity: 422 – 5,626 kW / 120 – 1,600 TR
  4. Application: Combined heat and power (CHP), commercial cooling

MEDIUM PRESSURE STEAM AND LOW TEMPERATURE HOT WATER

  1. Steam Gene-Link
  2. Model: YHAU-CW-J
  3. Capacity: 422 – 14,067 kW / 120 – 4,000 TR
  4. Application: Combined heat and power (CHP), industrial process cooling

HOT WATER, STEAM, DIRECT FIRED

  1. Low Leaving Chilled Water Temperature (Down to -5°C)
  2. Model: YHALC-LL
  3. Capacity: 176 – 1,758 kW / 50 – 500 TR
  4. Application: Industrial process cooling / refrigeration

HOT WATER, STEAM, DIRECT FIRED

  1. Absorption Heat Pump (Up to 90°C)
  2. Model: YHAP
  3. Capacity: Custom
  4. Application: District heating, industrial process heating